Skip to Content
DCNM-CBCPLR DCNM-CBCPLR Request a Quote

Arriving

DCNM-CBCPLR

Cable couplers that join two DICENTIS system cables without tools, or link a DICENTIS cable to standard CAT-5e and a 48 V supply: for longer runs, floor boxes and a rostrum microphone that is not always connected. Pack of 6. Scroll down for details.

Rs. 0 Rs. 0

  • Brand - BOSCH
BOSCH
BOSCH

Global leader in Public Address, Voice Evacuation and Conference Systems.

DICENTIS

DCNM-CBCPLR

Cable coupler

Pack of 6 | Joins DICENTIS cables | CAT-5e + 48 V DC in | Max 3 A

Flexible connections for DICENTIS systems

Extend cable runs

Join DICENTIS cable assemblies to adapt cable length to the installation, within the system’s permitted cable-length limits.

Connect temporary devices

Create a floor-pod connection point for equipment connected only when needed, such as a rostrum microphone.

Reuse CAT-5e infrastructure

Interface DICENTIS cable assemblies with standard CAT-5e cabling combined with a separate power cable.

Introduce power locally

Connect a suitable external power supply near participant devices, following Bosch’s specified supply requirements.

Add a system power-on switch

Use two couplers and a switch in the Bosch-documented circuit to turn on the DICENTIS system.

Secure the connection point

Fix the coupler to a flat surface with two screws, or use its recessed cable-tie provision to prevent sideways movement.

Bosch-DCNM-CBCPLR-Datasheet.pdf
Download
Bosch-DCNM-CBCPLR-EU-Declaration-of-Conformity.pdf
Download

Key specs

  • Pack of 6 couplers
  • Joins two DICENTIS cable assemblies, no tools
  • DICENTIS cable to CAT-5e plus power cable
  • External supply: 48 V DC (47 to 49 V), max 3.0 A
  • Mounts with two 2.5 mm screws, e.g. in a floor pod
  • 23 x 77 x 29 mm, 35 g
  • Jet black (RAL 9005)
Chat on WhatsApp

Bosch DCNM-CBCPLR Technical Specifications

Electrical

SpecificationDetails
Supply Voltage48 V DC nominal; permitted range: 47–49 V DC
Supply Ripple<200 mV peak-to-peak
Maximum Current3.0 A — maximum coupler input current; external power supply output must not exceed this value or must be limited to it

Mechanical

SpecificationDetails
MountingUsing two 2.5 mm screws
Dimensions — H × W × D23 × 77 × 29 mm (0.90 × 3.03 × 1.14 in)
Weight0.035 kg (0.077 lb)
ColourJet black, RAL 9005

Environmental

SpecificationDetails
Operating Temperature+5°C to +45°C
Storage Temperature−5°C to +45°C
Operating Relative Humidity5–90%, non-condensing

External Power Supply — Manufacturer Recommendations

The separately sourced external power supply must meet the electrical requirements above. Bosch additionally recommends:

ParameterRecommendation
Short-Circuit ProtectionSupply should have its own protection
Short-Circuit Output Current4.3–5.0 A
Automatic Restart Interval, if supported3–4 seconds
Maximum Automatic Restart AttemptsFour
Output Voltage After Switch-Off<9 V
Output Current After Switch-Off<1 mA

Parts Included

QuantityComponent
6DCNM-CBCPLR cable couplers

Ordering Information

FieldDetails
Model / CTNDCNM-CBCPLR
Product NumberF.01U.335.531
System FamilyDICENTIS
Questions & answers

Know before you buy

Quick answers about the DCNM-CBCPLR, and how it compares.

What is the cable coupler used for?

It joins two DICENTIS system cables without tools to make a longer run, or connects a DICENTIS cable to standard CAT-5e cable and a 48 V DC power supply.

Can I use it for a rostrum microphone that is not always connected?

Yes. Mount the coupler in a floor box as the fixed end of the cable, and plug in the device cable only when it is needed. It fixes with two 2.5 mm screws.

What power supply can I connect through it?

A 48 V DC supply (47 to 49 V), ripple under 200 mV, limited to 3.0 A. Bosch advises a supply with its own short-circuit protection.

How many are in a pack?

Six couplers.

Who supplies and supports this in Pakistan?

ESCO is the authorized distributor of Bosch, Dynacord and Electro-Voice in Pakistan. Products carry a 3-year carry-in warranty, and prices are quoted per project.

Chat on WhatsApp
WhatsApp