- 8 zone keys plus all-call
- Chime before the announcement
- Gooseneck microphone
- CAT5 connection to the T-8000 controller
- Up to 4 consoles per system
- Expandable with up to 4 T-8000AE keypads (32 zones)
| Function | Remote paging console for the T-8000 matrix |
| Microphone | Condenser gooseneck, 5mV/600Ω |
| Zones | 8 zone selector keys plus all-zone paging key |
| Chime | 2 or 4 tones, selector and off switch, own volume control |
| Connection | CAT5 to the T-8000 (RS485 control + audio on one cable) |
| Frequency response | 50Hz-18kHz (±2dB) |
| Signal-to-noise | Better than 75dB |
| THD | Less than 0.1% at 1kHz |
| Signal output | 0.775V/600Ω |
| Indicators | Zone, all-zone, busy, paging, power and output level |
| Power supply | DC 24V/2A with reverse fuse protection, 5W |
| Dimensions / weight | 200 x 142.7 x 51.5mm, 2.22kg |
| Expansion | Up to 4 T-8000AE keypads (71 x 143 x 52mm, 0.54kg each) for 32 zones |
Know before you buy
Quick answers about the T-8000A, and how it compares.
What is the ITC T-8000MA?
An intelligent broadcast matrix controller: 8 audio sources, 32 zones, a 7-inch touchscreen, USB playback, 500 scheduled tasks and fire alarm linkage in one 1U box. It runs the sound of a whole building without a computer or an operator.
Is the T-8000MA an IP system?
Yes. The T-8000RM paging mics, wall control panels and amplifiers all connect over normal network cable through a LAN switch. There is no server and no software to install; the touchscreen is the brain.
T-8000MA or T-8000, which one should I pick?
The T-8000MA covers 32 zones from one box and adds scheduling, USB playback, a satellite clock and 16 fire triggers. The T-8000 is a manual analog matrix: 8 zones per unit, up to 4 linked units for 32 zones, no scheduling or playback. Pick the T-8000 only when you want simple manual routing.
T-8000MA or the ITC IP Network PA (T-7700)?
For one building with up to 32 areas and no IT involvement, the T-8000MA is enough. For many buildings, hundreds of zones or management from a PC, use the T-7700 IP Network PA platform. Ask us and we will size it for you.
How do azaan and bell schedules work?
You store up to 500 timed tasks, daily, weekly or monthly. The built-in satellite clock keeps the time exact, and the audio plays automatically from USB or TF card, in the zones and at the volume you set.
What happens when the fire alarm trips?
The T-8000MA has 16 fire alarm trigger inputs plus ALERT and EVAC inputs. The alarm message overrides whatever is playing in the selected zones, and a 24V output can force other devices on.
Which amplifiers work with the T-8000MA?
Two ways: TC-X4500 series network amplifiers connect directly over the LAN (available on request), or the TS-P8816R decoder gives 16 analog outputs for ordinary ITC 100V amplifiers such as the TI and T series.
How do I page from my desk?
Connect up to 4 T-8000RM network paging microphones anywhere on the LAN. Each one can call a single zone, a group or all zones, with a chime first. T-8000CA and T-8000CB wall panels are available on request.