Skip to Content

Out of stock

PRA-CSLD

The Bosch PRA-CSLD is the PRAESENSA desktop call station: gooseneck microphone, a 4.3" colour touch screen that guides every call, dual OMNEO ports with redundant PoE, and up to 4 PRA-CSE extensions. Scroll down for details.

Rs. 0 Rs. 0

  • Brand - BOSCH
BOSCH
BOSCH

Global leader in Public Address, Voice Evacuation and Conference Systems.

Bosch PRAESENSA public address and voice alarm system: operator at a reception desk with the PRA-CSLD call station Bosch, Invented for life

IP-connected and fully-featured

PRAESENSA Public Address and Voice Alarm System

PRAESENSA system components

PRA-CSLD PRAESENSA Desktop Call Station

Desktop call station with gooseneck microphone and a 4.3" colour touch screen that guides the operator through every call; dual OMNEO ports with redundant PoE.

  • 4.3" Touch Screen
  • Up to 4 PRA-CSE Extensions
  • EN 54-16 ISO 7240-16
PRA-CSLD

PRA-CSLD · Product drawings

See the PRA-CSLD from every side

The top side and back side of the call station, in detail.

.
Top side · 01 / 02PRA-CSLD top side.
.
Top sideTouch screen, status indicators, microphone and press-to-talk.

PRA-CSLD · Key features

Made for every announcement

Explore the key capabilities of the Bosch PRAESENSA PRA-CSLD call station. Click a feature to see it in detail.

Features

PRAESENSA · Application areas

Ideal for mid-to-large sites

Click a site to see how PRAESENSA zones it, with an example bill of quantities. Existing systems on site can be integrated with new PRAESENSA buildings.

LIBRARYQuiet
LECTURE HALLS● Announcement
LABS● Paging · 70%
CAFETERIA● Music · 50%
CAMPUS GROUNDS● Music · 35%
ROOF · TERRACE● Music · 40%
FLOOR 3 · GUEST ROOMSQuiet
FLOOR 2 · CONFERENCE● Announcement
FLOOR 1 · RESTAURANT● Music · 55%
GROUND · LOBBY● Music · 60%
BUILDING A · EXISTING SYSTEMBUILDING B · NEW PRAESENSA
FLOOR 2 · SHOPS● Music · 50%
FLOOR 1 · FOOD COURT● Music · 65%
GROUND · ATRIUM● Promotion · 70%
PARKING● Parking notice
FLOOR 3 · CINEMAQuiet
FLOOR 2 · FASHION● Music · 45%
FLOOR 1 · KIDS ZONE● Music · 40%
GROUND · ENTRANCE● Parking notice
OMNEO / IPLIVE CALL SYNCPRA-SCL
TERMINAL HALL● Boarding call
GATES A–D● Paging · 75%
CHECK-IN● Music · 35%
BAGGAGE CLAIM● Paging · 60%
AIRSIDEEvacuation ready
ICUQuiet
OPERATING THEATRESQuiet
WARDS● Staff paging · 40%
OPD · WAITING● Music · 30%
EMERGENCY● Code call
CONTROL ROOMSupervised
PROCESS AREA● Alarm tone
LOADING BAY● Paging · 90%
WORKSHOP● Paging · 80%
ADMIN BLOCK● Music · 30%
Customer stories

PRAESENSA protects airports, stadiums, hotels and campuses around the world.

Ask for references →

01 / 07 · Universities

Universities

“When choosing a university, students and their families value a safe and secure teaching and learning environment.”

  • Loud in labs, quiet in libraries
  • Phased evacuation to local rules
  • Staff adjust music across campus

Example site: campus with 5 buildings

48zones
4call stations
296speakers

Example BOQQty

PRA-SCLSystem controller1
PRA-MPS3Power supply + battery charger3
PRA-AMPLAmplifier, 600 W3
PRA-CSLDCall station4
Ceiling speakersHalls, classrooms, library220
Wall / cabinet speakersCorridors, cafeteria60
Horn speakersCampus grounds16

Indicative quantities for an example site. Your system is sized by our engineers. Request a BOQ →

02 / 07 · Hotels

Hotels

“Hotel guests who feel right at home are more likely to enjoy repeat visits and make recommendations.”

  • Music changes by time and season
  • Calm audio near guest rooms
  • Multilingual message library

Example site: 12-floor city hotel

26zones
2call stations
196speakers

Example BOQQty

PRA-SCLSystem controller1
PRA-MPS3Power supply + battery charger2
PRA-AMPLAmplifier, 600 W2
PRA-CSLDCall station2
Ceiling speakersLobby, corridors, restaurant160
Wall speakersConference, spa24
Outdoor speakersTerrace, pool12

Indicative quantities for an example site. Your system is sized by our engineers. Request a BOQ →

03 / 07 · Shopping malls

Two buildings, one system

“Happy, informed shoppers stay longer and buy more.”

  • Connects with the PA system already on site
  • One announcement across both buildings
  • Music, promotions and notices per zone

Example site: existing mall + new extension

40zones
3call stations
344speakers

Example BOQQty

PRA-SCLSystem controller (new building)1
IntegrationLink to existing PA system1
PRA-MPS3Power supply + battery charger4
PRA-AMPLAmplifier, 600 W4
PRA-CSLDCall station3
Ceiling speakersShops, food court, atrium320
Horn speakersParking24

Indicative quantities for an example site. Your system is sized by our engineers. Request a BOQ →

04 / 07 · Airports

Airports

Clear, timed announcements across every terminal and gate.

  • Gate and boarding calls by zone
  • Phased evacuation of concourses
  • Multilingual pre-recorded messages

Example site: terminal with 24 gates

96zones
10call stations
600speakers

Example BOQQty

PRA-SCLSystem controller (redundant pair)2
PRA-MPS3Power supply + battery charger8
PRA-AMPLAmplifier, 600 W8
PRA-CSLDCall station (gate desks)10
Ceiling speakersHalls, gates, baggage520
Projector / horn speakersAirside, high ceilings80

Indicative quantities for an example site. Your system is sized by our engineers. Request a BOQ →

05 / 07 · Hospitals

Hospitals

Staff calls reach the right ward without disturbing patients.

  • Code calls to selected areas
  • Quiet ICU and operating theatres
  • EN 54-16 voice evacuation

Example site: 8-floor general hospital

60zones
6call stations
400speakers

Example BOQQty

PRA-SCLSystem controller (redundant pair)2
PRA-MPS3Power supply + battery charger4
PRA-AMPLAmplifier, 600 W4
PRA-CSLDCall station (nurse stations)6
Ceiling speakersWards, OPD, corridors360
Wall speakersEmergency, stairwells40

Indicative quantities for an example site. Your system is sized by our engineers. Request a BOQ →

06 / 07 · Oil & gas refineries

Oil & gas refineries

Intelligible alarms and paging over high-noise process areas.

  • Alarm tones and paging per area
  • Supervised lines and redundancy
  • Control room keeps full status

Example site: process plant with 18 zones

18zones
3call stations
130speakers

Example BOQQty

PRA-SCLSystem controller (redundant pair)2
PRA-MPS3Power supply + battery charger3
PRA-AMPLAmplifier, 600 W3
PRA-CSLDCall station3
Horn speakersProcess area, loading bay110
Wall speakersControl room, admin20

Indicative quantities for an example site. Your system is sized by our engineers. Request a BOQ →

07 / 07 · References

References

Decades of Bosch public address design experience, with PRAESENSA running in sites worldwide.

  • Airports, metros and stadiums
  • Hotels, malls and campuses
  • Ask esco.pk for local references
Ask for references →


1064861063-User-Manual.pdf
Download
Bosch-PRAESENSA-Installation-Manual.pdf
Download
PRA_CSLD_Data_sheet_enUS_76035360395 (1).pdf
Download
praesensa-commerical-brochure.pdf
Download

Key specs

  • 4.3" full-color capacitive touch screen
  • Gooseneck unidirectional microphone, 100 Hz – 14 kHz
  • PoE powered (802.3af), dual network ports
  • Business and EN 54-16 emergency use
  • Up to 4 PRA-CSE extensions, 12 buttons each
  • Supervised mic, audio path and network
  • 3.5 mm music input, built-in monitor speaker
  • 62 x 130 x 189 mm, 0.9 kg

Specifications

General

SpecificationValue
ModelPRA-CSLD
Order numberF.01U.325.048
Product typeDesktop LCD call station
SystemBosch PRAESENSA

Microphone

SpecificationValue
TypeGooseneck, unidirectional
Nominal acoustic input level80 – 100 dB SPL (configurable)
Maximum acoustic input level120 dB SPL
Signal-to-noise ratio≥ 70 dBA
Self noise< 26 dB SPL
Frequency response100 Hz – 14 kHz

Display

SpecificationValue
Size4.3"
TypeCapacitive touch screen, 24-bit color
Resolution480 × 272 px
Brightness300 cd/m²

Monitor Loudspeaker

SpecificationValue
Max SPL at 1 m75 dB SPL
Volume controlMute, -40 dB to 0 dB
Frequency range (-10 dB)400 Hz – 8 kHz

Line Input

SpecificationValue
Connector3.5 mm jack, stereo to mono
Signal-to-noise ratio≥ 96 dBA
Frequency response (-3 dB)20 Hz – 20 kHz
THD+N0.1%

Controls & Indicators

SpecificationValue
ControlsPress-to-talk button (recessed), touch screen
IndicatorsPower, identification, system fault, business call status (green), emergency call status (red)
ExtensionsUp to 4 × PRA-CSE (12 buttons each), via RJ12
Access controlUser number and PIN code

Power

SpecificationValue
PoE inputIEEE 802.3af Class 3
Nominal voltage48 V DC (37 – 57 V DC)
Power consumption, business use4.2 W
Power consumption, emergency use5.4 W
Per PRA-CSE extension0.1 W (indicators off) / 1.0 W (indicators on)

Supervision

SpecificationValue
MicrophoneCurrent
Audio pathPilot tone
Controller continuityWatchdog
PoE (1–2)Voltage

Network

SpecificationValue
Ethernet2 ports, 100BASE-TX / 1000BASE-T, PoE PD
ProtocolsTCP/IP, OMNEO
RedundancyRSTP
Latency10 ms
Audio encryptionAES128
Control securityTLS

Reliability & Environmental

SpecificationValue
MTBF1,000,000 h (Telcordia SR-332)
Operating temperature-5°C to +50°C (23°F to 122°F)
Storage temperature-30°C to +70°C (-22°F to 158°F)
Humidity (non-condensing)5% – 95%
Altitude-500 m to 5,000 m

Mechanical

SpecificationValue
Dimensions (H × W × D, excl. microphone)62 × 130 × 189 mm
Weight0.9 kg
IP ratingIP30
MaterialPlastic, Zamac
ColorRAL 9017 Traffic Black, RAL 9022 Pearl Light Grey

Certifications

CategoryStandard
Emergency (Europe)EN 54-16
InternationalISO 7240-16
MaritimeDNV GL Type Approval, EN 60945
Emergency complianceEN 50849, BS 5839-8
SafetyEN/IEC/CSA/UL 62368-1
ImmunityEN 55035, EN 50130-4
EmissionsEN 55032, EN 61000-6-3, ICES-003, FCC-47 Part 15B Class A
RailwayEN 50121-4
EnvironmentEN/IEC 63000

Parts Included

QuantityComponent
1Desktop LCD call station
1Bracket (attached to bottom)
1Connector cover (attached to bottom)
1Quick installation guide
1Safety and security information
Questions & answers

Know before you buy

Quick answers about the PRA-CSLD, and how it compares.

Where does the PRA-CSLD fit?
The operator’s desk of a Bosch PRAESENSA system: live announcements, recorded messages and background music control from a 4.3" touch screen, connected to the [PRA-SCL] or [PRA-SCS] controller over the network.
Do I need the PRA-CSE extension?
Yes, for most setups. Without a [PRA-CSE] the call station only works with pre-set zones. Each extension adds 12 buttons with zone status LEDs, up to four per call station. At least one is required for EN 54 voice alarm use.
How is it powered and connected?
One shielded network cable carries audio, control and PoE power (IEEE 802.3af Class 3). Add a second cable for redundant network and power. Either one alone keeps it fully working.
Can it be used for emergency announcements?
Yes. With the fireman’s interface configured and at least one [PRA-CSE] connected, it meets EN 54-16 and ISO 7240-16. Critical alarm functions are on physical buttons for operators wearing gloves.
Can I play music from a phone or laptop?
Yes. Plug into the 3.5 mm line input. The music becomes available on the network and can play in any speaker zone.
How does a PRAESENSA system fit together?
The [PRA-SCL] or [PRA-SCS] system controller is the brain: it routes all audio, plays messages and supervises every device. [Amplifiers], [multifunction power supplies] with battery backup and [call stations] all connect over one IP network using OMNEO, with loop-through cabling for redundancy. Up to 250 devices and 500+ zones per system, certified to EN 54-16 and ISO 7240-16.
Who supplies Bosch PRAESENSA in Pakistan, and what warranty do I get?
Electronic Security Company (ESCO) is the only authorized distributor of Bosch, Dynacord and Electro-Voice in Pakistan, so every PRAESENSA product we supply is genuine and comes with a 3-year warranty. Warranty is carry-in: bring the unit to an ESCO office and after inspection it is repaired or replaced as needed.
Similar Products