Multi-IR Flame Detection Camera
Hikfire HF-VR343 Multi-IR Sensor + Professional AI flame detector + 2 IR Ref 4MP Fire Detection Camera
AI Intelligent Detection
Support AI intelligent detection: Smoke & flame detection, Indoor access blocked alarm, On/off duty alarm, Dangerous goods detection, Dangerous behaviour detection, Fire Extinguisher Detection, Area Invasion Detection.
Audio
Built-in Speaker & Microphone, supports two-way voice intercom
Sensor Type
Infrared pyroelectric: 4.3 um + 3.8 um, further enhancing the accuracy of flame alarms.
Resolution
Main Stream: 25 fps (2560 × 1440, 1920 × 1080, 1280 × 720)
Sub Stream: 25 fps (704 × 576, 640 × 480,352 × 288)
Detector
Thermography Alarm Shielded Area: Configure four rectangular areas
1/2.7" Progressive Scan CMOS ,
Detection Range: within 30 meters(0.1 square meter fire pan)
Fire and Smoke Detection: Yes
IR Range
Supports 30m infrared illumination
Intelligent Fusion Camera
supporting flame detection by sensing changes in infrared signals around the flame, & capable of video verification.
Key specs
- Hikfire fusion fire detection camera, 4 MP (2560 x 1440 at 25 fps), 4 mm lens (79° horizontal), WDR 120 dB
- Built-in infrared pyroelectric flame detector (4.3 um + 3.8 um): senses the flicker of a flame within 30 m (98 ft, 0.1 m² fire pan) and verifies it on video
- AI detection: smoke and flame, blocked indoor exit route, on/off duty, dangerous goods, dangerous behaviour, missing fire extinguisher, area intrusion
- Local alarm light (red alarm, green normal, yellow fault); built-in speaker and microphone, two-way talk, remote silence; OSD alarm overlay
- 30 m (98 ft) infrared; 3D DNR, BLC
- 2 alarm in, 2 alarm out; 1 audio in and out; 12 VDC 1 W auxiliary output to power a smoke or gas sensor
- microSD up to 256 GB, NAS; ONVIF, ISAPI; Hik-Connect; 4G or LAN
- Power: PoE or 9 to 30 VDC, 18 W max; IP67; -30 to 60 °C (-22 to 140 °F)
- Φ 130 x 101 mm, 407 g; mounting wall 2.4 to 2.8 m (8 to 9 ft), pendant 3.3 to 6 m (11 to 20 ft)
|
Camera |
|
|
Sensor Type |
Infrared pyroelectric: 4.3um + 3.8 um |
|
Max. Resolution |
2688×1520 |
|
Main Stream |
25 fps (2560 × 1440, 1920 × 1080, 1280 × 720) |
|
Sub Stream |
25 fps (704 × 576, 640 × 480, 352 × 288) |
|
Min. Illumination |
Color: 0.01 Lux @ (F1.6, AGC ON) |
|
Lens |
Horizontal: 78.96°, Vertical:43.17°, Diagonal: 93.31° |
|
Image Settings |
Saturation, brightness, contrast, sharpness, AGC and white balance can be adjusted through the client or browser |
|
Adjusted Angle |
Horizontal: 0° ~ 360°; Vertical: 0° ~ 70° |
|
WDR |
120 dB |
|
Shutter |
1/25 ~ 1/100,000 s |
|
Day/Night Switch |
IR cut filter |
|
Image Enhancement |
BLC, 3D DNR |
|
SVC Encoding |
H.264, H.265 |
|
H.265 |
Main Profile |
|
H.264 |
Main Profile / High Profile |
|
Main Stream Video Compression Standard |
H.265/H.264 |
|
Sub Stream Compression Standard |
H.265/H.264 |
|
Video Bitrate |
256Kbps ~ 8192Kbps |
|
General |
Anti flicker, Heartbeat, Mirror, Password protection |
|
Intelligent Alarm |
Smoke and flame detection, Indoor access blocked alarm, On/off duty alarm, Dangerous goods detection, Dangerous behaviour detection, Fire Extinguisher Detection, Area Invasion Detection |
|
Exception Detection |
Motion detection, Video tampering alarm, Network cable disconnection, IP address conflict, Invalid access, Full memory, Memory error |
|
WEB& Configuration |
Support web preview, configuration and parameter import/export |
|
Protocol |
TCP/IP, HTTP, HTTPS, DHCP, DNS, RTP, RTSP, RTCP, NTP, IPv4, UDP |
|
Storage |
Support MicroSD / MicroSDHC / MicroSDXC card (max. 256 G), disconnection local storge, NAS |
|
Interface Protocol |
ONVIF (PROFILE S, PROFILE G), ISAPI, EZVIZ |
|
IR Range |
30 m |
|
Accessory Type |
Wall mounted support, pendent support, universal joint |
|
Detector |
|
|
Thermography Alarm Shielded Area |
Configure four rectangular areas |
|
Image Sensor |
1/2.7" Progressive Scan CMOS |
|
Alarm Indicator Light |
One, Red: Alarm; Yellow: Fault; Green: Normal |
|
Detection Range |
within 30 meters (0.1 square meter fire pan) |
|
Fire and Smoke Detection |
Yes |
|
Function |
|
|
Remote Silence |
Yes |
|
Interface |
|
|
Alarm Interface |
2-way alarm input (Alarm in), 2-way alarm out (Alarm out) |
|
Audio Interface |
1 built-in microphone, 1 built-in speaker, Supports voice intercom |
|
Auxiliary Power Interface |
Supports DC 12V output, power 1W |
|
Ethernet Interface |
1 RJ45 10 M/100 M adaptive Ethernet port |
|
General |
|
|
Power |
DC 12V ± 25% |
|
Dimension (φ × H) |
Φ130× H101mm |
|
Weight |
407g |
|
Execution Standard |
Q/HKD 006-2019 |
|
Mounting Height |
Wall mounted: 2.4 m~2.8 m, Pendent: 3.3 m~6 m |
|
Ingress Protection |
IP67 |
|
Communication Mode |
HF-VR343: LAN |
Know before you buy
Quick answers about the HF-VR343 4mm, and how it compares.
How is a fire detection camera different from a smoke detector?
A smoke detector waits for smoke to reach the ceiling. A fire detection camera watches the area: the HF-VH series senses the temperature of what it sees and alarms when something gets too hot, and the HF-VT fusion models also see a flame at a distance and smoke in the picture, so the alarm comes earlier and the operator can check it on video. It is an extra layer for a kitchen, warehouse, substation or store room, not a replacement for the fire alarm system the building code asks for.
Can I buy this online?
Hikvision security products are installed products, so we start with a free pre-sales consultation: our engineers suggest the right model and everything that goes with it for your site and send a quote. Use Request a Quote on this page, contact us or WhatsApp +92 300 ESCO 301. Offices in Karachi, Lahore, Islamabad and Rawalpindi. 1 year carry-in warranty.
Standalone, interlinked or panel: which smoke alarm do I need?
A standalone alarm (HF-S2, HF-S3E) sounds only where the smoke is; fine for a shop, a store room or one flat. Interlinked alarms (HF-S3E-R) talk to each other by radio, so a fire in the kitchen wakes the bedrooms upstairs; right for a house, hostel or guest house, with no wiring. A building with many rooms, a basement or an escape route that must be managed needs a fire alarm panel with wired detectors, which the fire code usually asks for; Ask us and we design it. The Hikfire cameras add early warning to any of these but do not replace the panel.