Fire Detection Camera
Hikfire HF-VR344 Multi-IR Sensor + Professional AI flame detector + 3 IR Ref 4MP Fire Detection Camera
Resolution
Main Stream: 25 fps (2560 × 1440, 1920 × 1080, 1600×1200, 1280 × 720)
Sub Stream: 25 fps (704 × 576, 640 × 480, 352 × 288)
Interface
Supports 2 alarm input/output channels, 1 audio input/output channel and 1 RS485, Support microSD/SDHC/SDXC card(128 G) local storage.
IR Range
IR Distance: Up to 30m
Intelligent Fusion Camera
Supporting flame detection by sensing changes in infrared signals around the flame, and capable of video verification.
Intelligent Alarm
Motion Detection, Video tampering alarm, Intrusion detection, Boundary violation detection, Smoke and fire detection
Sensor Type
Optical: 1/2.7" Progressive Scan CMOS
Flame: 4.3um (main) + 5.0um (auxiliary) + 3.8um (auxiliary)
Features
Supports low bitrate, low latency, Region of Interest enhanced encoding, and SVC (Scalable Video Coding) adaptive encoding technology.
Key specs
- Hikfire fusion flame detection camera, 4 MP (2560 x 1440 at 25 fps), 4 mm F1.6 (84° horizontal), WDR 120 dB, full colour
- Built-in 3-band infrared pyroelectric flame detector (4.3 um main, 5.0 and 3.8 um auxiliary) for fewer false alarms; flame detection range under 50 m (164 ft) with video verification
- AI: smoke and fire detection, intrusion, line crossing; alarm pictures and clips linked to each alarm
- Local alarm light (red alarm, green normal, yellow fault), voice alarm, remote silence
- 2 alarm in, 2 alarm out (30 VDC 2 A); line in and out; RS-485; 4 to 20 mA current output for a fire alarm panel
- ROI and SVC encoding; microSD up to 128 GB; Hik-Connect; ONVIF, ISAPI
- Power: PoE (802.3at) or 9 to 36 VDC, 24 W max; IP66; -20 to 60 °C (-4 to 140 °F)
- 212.5 x 130 x 84.8 mm, 1.4 kg; mounting indoor above 2.5 m (8 ft), outdoor above 3.5 m (11.5 ft)
|
Camera |
|
|
Sensor Type |
Optical: 1/2.7" Progressive Scan CMOS Flame: 4.3um (main) + 5.0um (auxiliary) + 3.8um (auxiliary) |
|
Max. Resolution |
2560 × 1440 |
|
Main Stream |
25 fps (2560 × 1440, 1920 × 1080, 1600 × 1200, 1280 × 720) |
|
Sub Stream |
25 fps (704 × 576, 640 × 480, 352 × 288) |
|
Min. Illumination |
Color: 0.015 Lux@ (F1.6, AGC ON) |
|
Lens |
4 mm, F1.6 |
|
FoV |
Horizontal: 84°, Vertical: 43° |
|
Image Settings |
Saturation, brightness, contrast, sharpness, AGC & white balance can be adjusted through the client or browser. |
|
Shutter |
1/25 ~ 1/100,000 s |
|
WDR |
120 dB |
|
Day/Night Switch |
Full color |
|
Image Enhancement |
Backlight compensation, 3D digital noise reduction, gray scale range adjustment |
|
Sub Stream Compression Standard |
H.265, H.264 |
|
Main Stream Video Compression Standard |
H.265, H.264 |
|
Video Bitrate |
256Kbps~8Mbps |
|
Intelligent Alarm |
Motion Detection, Video tampering alarm, Intrusion detection, Boundary violation detection, Smoke and fire detection |
|
Protocol |
TCP/IP, FTP, HTTP, HTTPS, DHCP, DNS, DDNS, RTP, RTSP, RTCP, NTP, UDP |
|
Interface Protocol |
ONVIF (PROFILE S, PROFILE G), ISAPI, EZVIZ |
|
WEB Configuration |
Support web preview, configuration and parameter import/export |
|
General |
Reset, anti-flicker, heartbeat, mirror, password protection, video occlusion, IP address filtering |
|
Storage |
MicroSD/SDHC/SDXC card (128 G), disconnection local storge |
|
Exception Detection |
Network cable disconnection, IP conflict, Invalid access, Full memory, Memory error |
|
Power Consumption |
≤10 W |
|
IR Range |
< 30 m |
|
Accessory Type |
Wall mounted support, pendent support, universal joint |
|
Detector |
|
|
Fire and Smoke Detection |
Yes |
|
Detection Range |
< 50m |
|
Alarm Indicator Light |
One, Red: Alarm; Green: Normal; Yellow: Fault |
|
Function |
|
|
Remote Silence |
Yes |
|
Interface |
|
|
Alarm Interface |
2-way alarm input (Alarm in), 2-way alarm output (Alarm out, support DC 30V/2A or AC 125V/0.5A) |
|
Audio Interface |
1 way audio input (Line in), 1 way audio output (Line out) |
|
General |
|
|
Using Environment |
Temperature: -20 °C~60 °C, humidity: less than 95% (on condensing) |
|
Ingress Protection |
IP66 |
|
Communication Interface |
RJ45 10 M/100 M adaptive Ethernet port * 1, support PoE power supply; RS-485 interface * 1 |
|
Mounting Height |
Indoor: higher than 2.5 m Outdoor: higher than 3.5 m |
|
Power Interface Type |
3pin industrial terminal, spacing: 3.81 |
|
Power |
DC 9V~DC 36V, 24W MAX; PoE: 802.3at, CLASS 4 |
|
Product Implementation Standard |
Q/HKD 035-2022 |
|
Weight |
1.4 kg (without packing), 1.7 kg (with packing) |
|
Dimension (L × W × H) |
212.5 mm × 130.0 mm × 84.8 mm |
Know before you buy
Quick answers about the HF-VR344 4mm, and how it compares.
How is a fire detection camera different from a smoke detector?
A smoke detector waits for smoke to reach the ceiling. A fire detection camera watches the area: the HF-VH series senses the temperature of what it sees and alarms when something gets too hot, and the HF-VT fusion models also see a flame at a distance and smoke in the picture, so the alarm comes earlier and the operator can check it on video. It is an extra layer for a kitchen, warehouse, substation or store room, not a replacement for the fire alarm system the building code asks for.
Can I buy this online?
Hikvision security products are installed products, so we start with a free pre-sales consultation: our engineers suggest the right model and everything that goes with it for your site and send a quote. Use Request a Quote on this page, contact us or WhatsApp +92 300 ESCO 301. Offices in Karachi, Lahore, Islamabad and Rawalpindi. 1 year carry-in warranty.
Standalone, interlinked or panel: which smoke alarm do I need?
A standalone alarm (HF-S2, HF-S3E) sounds only where the smoke is; fine for a shop, a store room or one flat. Interlinked alarms (HF-S3E-R) talk to each other by radio, so a fire in the kitchen wakes the bedrooms upstairs; right for a house, hostel or guest house, with no wiring. A building with many rooms, a basement or an escape route that must be managed needs a fire alarm panel with wired detectors, which the fire code usually asks for; Ask us and we design it. The Hikfire cameras add early warning to any of these but do not replace the panel.