Intelligent Power Distribution
Dynamically allocates up to 600 W of total output power across four channels, matching connected loudspeaker loads for efficient power utilization.
Flexible AmplificationCategory | Specification | Details |
Amplifier | Amplifier Channels | 4 independent channels + 1 integrated spare channel |
| Combined Maximum Output Power | 600 W | |
| Combined RMS Power (specified EIAJ test) | 150 W | |
| Nominal Loudspeaker Output | 70 V RMS / 100 V RMS | |
| Loudspeaker Load (all channels, maximum) | 600 W | |
| Minimum Load Impedance — 100 V | 16.7 Ω | |
| Minimum Load Impedance — 70 V | 8.3 Ω | |
| Maximum Cable Capacitance | 200 nF | |
Digital Signal Processing | Per-Channel Master Equalizer | 7-band |
| Level Control | 0 dB to −60 dB; mute | |
| Level Control Resolution | 1 dB | |
| Audio Delay | 0–60 s | |
| Audio Delay Resolution | 1 ms | |
| Limiter | RMS power limiter | |
Audio Performance | Frequency Response (−3 dB) | 20 Hz–20,000 Hz |
| THD + Noise (at RMS power) | < 0.50% | |
| THD + Noise (6 dB below RMS power) | < 0.1% | |
| Intermodulation Distortion | < 0.10% | |
| Minimum SNR — 100 V mode | 110 dBA | |
| Minimum SNR — 70 V mode | 107 dBA | |
| Channel Crosstalk | < −84 dBA | |
| Audio Sample Rate | 48 kHz | |
| Audio Sample Size | 24-bit | |
Electrical | Nominal Power Supply Input | 48 V DC |
| Permitted Input Voltage | 44–60 V DC | |
| Power Supply Inputs | Dual inputs A/B | |
| Sleep Mode Consumption (no supervision) | 6 W | |
| Snooze Mode Consumption (supervision active) | 7.5 W | |
| Active Idle Consumption | 36 W | |
| Active Low-Power Consumption | 50 W | |
| Active RMS-Power Consumption | 222 W | |
| Consumption per Active Network Port | 0.4 W | |
Network & Security | Number of Ethernet Ports | 2 |
| Ethernet Types | 100BASE-TX; 1000BASE-T | |
| Ethernet Protocol | TCP/IP | |
| Control/Audio Protocol | OMNEO | |
| Network Redundancy | RSTP | |
| Network Audio Latency | 10 ms | |
| Audio Encryption | AES-128 | |
| Security | TLS | |
Supervision & Redundancy | Spare Channel | Integrated automatic amplifier-channel redundancy |
| Loudspeaker Output Redundancy | A/B groups; Class-A loop support | |
| End-of-Line Detection | 25.5 kHz pilot tone; 3 V RMS | |
| Network Interface Supervision | Link presence | |
| Amplifier Load Supervision | Short circuit | |
| DC Input Supervision | Undervoltage | |
| Thermal Supervision | Overheat | |
| Controller Continuity | Watchdog | |
Environmental | Operating Temperature | −5 °C to +50 °C |
| Storage Temperature | −30 °C to +70 °C | |
| Relative Humidity | 5–95% (non-condensing) | |
| Air Pressure | 560–1,070 hPa | |
| Installation Altitude | −500 m to +5,000 m | |
| Fan Airflow | Front to sides/rear | |
| Fan Noise — Idle (1 m) | < 30 dB SPL(A) | |
| Fan Noise — RMS Power (1 m) | < 53 dB SPL(A) | |
Mechanical | Dimensions (H × W × D) | 44 × 483 × 400 mm |
| Rack Height | 1U | |
| Ingress Protection | IP30 | |
| Housing Material | Steel; Zamac | |
| Color | RAL 9017 Traffic black | |
| Weight | 8.10 kg | |
Reliability | MTBF (calculated extrapolation) | 300,000 h |
Quick answers about the PRA-AD604, and how it compares.