Skip to Content
DCNM-FBD2 DCNM-FBD2 Request a Quote

Out of stock

DCNM-FBD2

The heart of a DICENTIS Flush seat for participants and chairpersons: the base device fits under the table or seat, or in an armrest, and the flush panels connect to it. It serves 2 participants, or up to 4 in dual use sharing microphone and loudspeaker, and loops through to the next base device on the DICENTIS system cable. Scroll down for details.

Rs. 0 Rs. 0

  • Brand - BOSCH
BOSCH
BOSCH

Global leader in Public Address, Voice Evacuation and Conference Systems.

Bosch DICENTIS Flush conference microphones built into a meeting room table with delegates seated

DICENTIS Flush range

Modular, IP-based conferencing with cost-effective installation convenience

Bosch DCNM-FBD2 Product Highlights

Explore the key capabilities of the Bosch DCNM-FBD2 Flush Base Device 2, designed for flexible participant setups and reliable DICENTIS Flush integration.

Standard 2-Participant Mode

Supports 2 participant positions as standard, with each input assignable to its own seat number.


Up to 4 Participant Positions

In dual use, the DCNM-FBD2 can support up to 4 participant positions with shared microphones and loudspeakers.

DICENTIS Loop-Through

Supports loop-through connection to other Flush base devices using the DICENTIS system cabling architecture.


Flexible Module Connectivity

Provides RJ12, balanced audio, RJ45 and loudspeaker connections for integrating button modules, microphone panels and loudspeakers.


Flexible Mounting Options

Can be installed under a tabletop or seat, in an armrest, wall-mounted or inside a cable duct.


Compact 48 VDC Base Device

Operates at 48 VDC with 5 W base-device power consumption, helping support compact flush-system installations.

Bosch DCNM-FBD2 Connectivity & Installation

Explore how the Bosch DCNM-FBD2 integrates with DICENTIS system cabling, flush button panels, microphones and loudspeakers for flexible conference installations.

Bosch DCNM FBD2 Connectivity Installation Diagram

DICENTIS System Connections

Two system connectors allow the DCNM-FBD2 to daisy-chain with DICENTIS cables for communication and power.

Loop-Through Connection

The DCNM-FBD2 can be daisy-chained to another Flush Base Device using DICENTIS cabling.

Button Panel Connections

RJ12 connections provide power and control for compatible button panels such as DCNM-FMICB and DCNM-FPRIOB.

Microphone Connections

Two balanced microphone connections are provided for DCNM-FMCP Flush Microphone Connection Panels.

Loudspeaker Outputs

Two loudspeaker outputs connect DCNM-FLSP Flush Loudspeaker Panels, supporting two participant seats.

Applications of Bosch DCNM-FBD2

The Bosch DCNM-FBD2 is designed for flush-mounted DICENTIS conference installations where participant controls, microphones and loudspeakers need to be integrated discreetly into furniture.

Bosch DCNM-FBD2 conference table installation

Conference Tables

Ideal for creating discreet flush-mounted participant positions within professional conference tables.

Bosch DCNM-FBD2 chair armrest installation

Chair Armrests

Supports clean integration inside chair armrests for compact and unobtrusive participant control positions.

Bosch DCNM-FBD2 under table installation

Under-Table Installations

Can be mounted under tabletops or seats to keep system hardware hidden while maintaining easy connectivity.

Bosch DCNM-FBD2 multi participant flush setup

Multi-Participant Flush Setups

Supports two participant positions as standard and up to four positions in dual use.

Enhanced User Experience

High-quality loudspeakers and microphones deliver clear audio, even when active together. Shock-mount design reduces noise, while identification secures voting. Language selection is automated for participant convenience.

Easy Integration

Flush modules work seamlessly with DICENTIS tabletop devices and the interpreter desk. Settings are adopted instantly without restart, while the server-based system supports third-party apps, cloud services, and remote maintenance.

Easy, Cost-Effective Installation

The DICENTIS Flush Range offers a modular design for any meeting type. It supports future upgrades, uses existing IP and PoE, and installs quickly with a click-to-fit mechanism. Sharing the Bosch DCN footprint, it allows easy replacement. Dual-seat setups can host up to four delegates, saving space and cost.

Versatile Microphone Options

Compact flush microphones fit where space is limited. The audio interface connects third-party microphones, supports extra inputs, and provides 48 V phantom power.

Structured Meetings

The modular design empowers specifiers and installers to tailor the system to different meeting types. With dual-seat setups supporting up to four delegate positions, meetings can be organized efficiently while saving space and cost.

Convenient Language Selection

Headphone language selection can be automated, ensuring participants quickly access their preferred interpretation channel. Seamless integration with the DICENTIS interpreter desk provides a fully ISO-compliant interpretation solution.

Parliamentary-Style Voting

Identification-based access allows controlled voting functionality, preventing fraud and ensuring accurate results. Voting can be managed directly through the DICENTIS Flush modules for structured decision-making.

Quick Identification

Each participant’s identification enables secure access to system features such as voting and language selection. This ensures smooth authentication and prevents unauthorized use during sessions.

DICENTIS Flush device with custom wood finish built into a conference table

Customize your DICENTIS Flush in wood, stone, metal or RAL color

Match DICENTIS Flush devices to any interior. System integrators, architects and end users can order custom finishes from the RAL Classic and RAL Design color palettes, or choose from a wide range of wood, stone and metal designs.

Lets Talk!

Get in touch for a free consultation, survey, pricing and demonstration session.

Bosch-DCNM-FBD2-EU-Declaration-of-Conformity.pdf
Download
Bosch-DCNM-FBD2-Quick-Installation-Guide.pdf
Download
Bosch-DCNM-FBD2-Technical-Datasheet.pdf
Download
Bosch-DICENTIS-Configuration-Manual.pdf
Download
Bosch-DICENTIS-Installation-Manual.pdf
Download

Key specs

  • 2 participants, up to 4 in dual use
  • RJ12 per participant, panels daisy-chain
  • 2 balanced audio inputs for DCNM-FMCP
  • 2 loudspeaker outputs for DCNM-FLSP
  • 2 x RJ45 system connectors, loop-through
  • 48 VDC, 5 W (base device only)
  • Under table or seat, armrest, wall, duct
  • 32 x 100 x 200 mm, 656 g

Bosch DCNM-FBD2 Flush Base Device 2 Technical Specifications

Review the key participant capacity, connectivity, power, mounting, mechanical and environmental specifications of the Bosch DCNM-FBD2.

Category Specification Official Value
General Product type Flush base device 2

System DICENTIS Flush

Standard participant positions 2

Maximum participant positions 4 with dual-use license

Shared resources in 4-position mode Microphones and loudspeakers
Functions Flush participant positions Creates flush-mounted participant positions with DICENTIS Flush panels

Loop-through Supports loop-through to another Flush base device

Status indication Green / amber LED
Interconnections Button module connections 2 × RJ12 connectors

Balanced audio inputs 2 × 3-pole terminal block inputs for DCNM-FMCP

System communication / power 2 × RJ45-compatible connectors

Loudspeaker outputs 2 × 2-pole terminal block outputs for DCNM-FLSP
Electrical Operating voltage 48 VDC

Power consumption — FBD only 5 W

Power consumption with modules Refer to Bosch Power Calculation tool
Mechanical Mounting type Wall-mounted, under tabletop or seat, in armrest or cable duct

Dimensions (H × W × D) 32 × 100 × 200 mm excluding cables

Dimensions (H × W × D) 1.26 × 3.90 × 7.90 in excluding cables

Weight 656 g / 1.45 lb

Colour RAL 9017 Traffic Black
Environmental Environmental classification IEC 60721: storage 1K3, transportation 2K2, operational 3K4

Operating temperature 5 °C – 45 °C / 41 °F – 113 °F

Operating temperature in enclosed duct 5 °C – 35 °C / 41 °F – 95 °F

Transportation temperature -30 °C – 70 °C / -22 °F – 158 °F

Storage temperature -5 °C – 45 °C / 23 °F – 113 °F

Operating relative humidity 5% – 90%, non-condensing
Identification CTN / Model DCNM-FBD2

Product Number F.01U.405.788
Questions & answers

Know before you buy

Quick answers about the DCNM-FBD2, and how it compares.

How many participants can one DCNM-FBD2 serve?

Two participant positions as standard: each input gets its own seat number. In dual use, one FBD2 serves up to four participants, two sharing each microphone and loudspeaker. On the wired DICENTIS system dual use needs no license. Up to four DCNM-FIDP identification panels can be connected in dual use.

What connects to the DCNM-FBD2?
2 x RJ45 system connectorsNetwork and power on the DICENTIS system cable, loop-through to the next FBD2
2 x RJ12Button and control panels, one port per participant. Several panels daisy-chain on one port: FMICB, FPRIOB, FSLP, FVP, FIDP
2 balanced audio inputsDCNM-FMCP microphone panels
2 loudspeaker outputsDCNM-FLSP loudspeaker panels
Headphone connectionAudio for the DCNM-FSLP, one per side
Where is the DCNM-FBD2 installed, and what is in the box?

Out of sight: under the tabletop or seat, in an armrest, on a wall or inside a cable duct (in a closed duct, up to 35 °C). Only the click-in panels show on the table. A green / amber LED shows the unit status.

In the box: the base device, a quick installation guide, an anti-take-out bracket, two 2 m and two 30 cm CAN cables.

What else do I need for a flush-mounted seat?

A DICENTIS Flush seat is built around the DCNM-FBD2 flush base device, fitted under the table or seat, in an armrest, on a wall or in a cable duct. Pick the panels the seat needs and cable them to the FBD2:

  • Microphone: DCNM-FMCP connection panel with a DCNM-MICSLS (310 mm) or DCNM-MICSLL (480 mm) screw-lock microphone, plus a DCNM-FMICB microphone button or DCNM-FPRIOB priority button. The button panel also powers the FMCP.
  • Loudspeaker: DCNM-FLSP.
  • Language selection: DCNM-FSLP and headphones.
  • Voting: DCNM-FVP.
  • Identification: DCNM-FIDP with the DCNM-FICH card holder (ask us).
  • No space on the table: DCNM-FHHC handheld microphone through a DCNM-FAI flush audio interface (ask us).

In dual use, one FBD2 serves up to four participants, two sharing each microphone and loudspeaker. For mounting, add DCN-FCOUP couplings, DCNM-FEC end caps and DCNM-FPT positioning tools. The FBD2 joins the system with DICENTIS system cables, powered from the DCNM-APS2 or DCNM-PS2.

Do DICENTIS Flush panels need a software license?

On the wired DICENTIS system, a Flush seat does basic discussion without a license once the system is registered: microphone, request to speak, loudspeaker, and dual use on the DCNM-FBD2.

These panels need a Premium or Ultimate license for each participant:

  • DCNM-FSLP: language selection at the seat
  • DCNM-FVP: voting
  • DCNM-FIDP: identification by NFC card

Order Premium DCNM-LPP-PE or Ultimate DCNM-LPU-PE, one license per participant; a dual use seat counts as two.

How are DICENTIS Flush panels mounted?

Every panel clicks into a 2 mm metal panel. In wood or any other surface, fit them with DCN-FCOUP flush couplings and finish both ends of the row with DCNM-FEC end caps (set of 50). DCNM-FPT positioning tools help place the couplings and include a template for the loudspeaker cut-out.

DICENTIS Flush uses the same installation footprint as Bosch DCN Flush devices (except the loudspeaker panel), so an older DCN Flush installation can be replaced without major rework.

Which other DICENTIS Flush parts can ESCO supply?

These are not in our online shop yet. Ask us for a quote:

  • DCNM-FIDP identification panel: NFC card reader that reads cards 0 to 1 cm away, so nobody logs in by accident. Up to four per DCNM-FBD2 in dual use.
  • DCNM-FICH ID card holder (pack of 25): keeps the card next to the FIDP, so the participant stays logged in while the card is parked and is logged out when it is removed. It takes the place of the end cap on that side.
  • DCNM-FAI flush audio interface: connects one third-party microphone or line-level source to the FBD2: balanced or unbalanced, 48 V phantom power, gain 0 to 18 dB, with a contact input for a custom microphone button. It also takes two DCNM-FMCP panels for a rostrum position. The DCNM-FHHC (coiled) and DCNM-FHH (straight 1.5 m cable) handheld microphones connect through it; two FAI give two handhelds per FBD2.
  • DCNM-FSL and DCNM-FSL2 flush language selectors: like the DCNM-FSLP, but stand-alone: each connects to a PoE switch with its own network cable, so no FBD2 is needed. The FSL2 can also be daisy-chained.
  • DCNM-FET flush extraction tools.
  • Headphones: LBB3443/00 and LBB3443/10 lightweight headphones, HDP-LWN neckband headphones and the HDP-ILN induction loop neckband.
Who supplies Bosch DICENTIS in Pakistan, and what warranty do I get?

Electronic Security Company (ESCO) is the only authorized distributor of Bosch, Dynacord and Electro-Voice in Pakistan, so every DICENTIS product is genuine and comes with a 3-year warranty. Warranty is carry-in: bring the unit to an ESCO office and after inspection it is repaired or replaced as needed.

We supply, design and install complete conference and voting systems for parliaments, government offices, boardrooms and auditoriums, with after-sales service nationwide. Prices are quoted per project: tell us your room and number of seats and we will send a quote.

Similar Products